·Î±×ÀÎ ¤Ó ȸ¿ø°¡ÀÔ ¤Ó Àå¹Ù±¸´Ï ¤Ó ÁÖ¹®/¹è¼ÛÁ¶È¸ ¤Ó ã¾Æ¿À½Ã´Â±æ ¤Ó Agency Shop
¼¼ÀÏ»óÇ° |  Á¦Ç°¼Ò°³ |  ¿Â¶óÀΰßÀû¼­ |  i-Shop |  °ü·Ã»çÀÌÆ® |  Manual |  ±â¼úÁ¤º¸ |  °í°´¼¾ÅÍ |  ¹°¹°±³È¯
Keyword or Catalog No (»óÇ°¸í.¸ðµ¨¸í.Á¦Á¶»ç¸í)    
¾ÆÀ̵ð
ºñ¹Ð¹øÈ£
¾ÆÀ̵ð ÀúÀå
¤¡. °ü·Ã»óÇ°º¸±â ¨¿
¤¤. °ü·Ã»óÇ°º¸±â ¨À
¤§. °ü·Ã»óÇ°º¸±â ¨Á
¤©. °ü·Ã»óÇ°º¸±â ¨Â
¤±. °ü·Ã»óÇ°º¸±â ¨Ã
¤². °ü·Ã»óÇ°º¸±â ¨Ä
¤µ. °ü·Ã»óÇ°º¸±â ¨Å
¤·. °ü·Ã»óÇ°º¸±â ¨Æ
¤¸. °ü·Ã»óÇ°º¸±â ¨Ç
¤º. °ü·Ã»óÇ°º¸±â ¨È
¤». °ü·Ã»óÇ°º¸±â ¨É
¤¼. °ü·Ã»óÇ°º¸±â ¨Ê
¤½. °ü·Ã»óÇ°º¸±â ¨Ë
¤¾. °ü·Ã»óÇ°º¸±â ¨Ì
* °úÇб³Àç (ÃÊ.Áß.°í)
* ±ÝÇü¼³°è.»çÃ⼺Çü
* ÁÖ¹®Á¦ÀÛÇ° (À¯¸®.Å×ÇÁ·Ð.±Ý¼Ó)
* ½Ã¾à. Àç·á.ÇÕ±Ý.Ÿ°Ù.¿þÀÌÆÛ
·¹µåºí·° Å×½ºÆ®¿ë  
±â¾÷ÀºÇà 086-023289-04-011
¿ì¸®ÀºÇà 048-401225-13-001
¿¹±ÝÁÖ : ±è¹Î¿Á
Alphabet Index
A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z

"DAIHAN" WiseClave WACS Autoclaves Steam Sterilizer 45-/60-/80-/100-Lit., up to 132¡É, 2 Kgf/cm2, °í¾Ð ¸ê±Õ±â wisecube-0115
Á¤»ó°¡ : 0¿ø
ÆǸŰ¡ :  VAT Æ÷ÇÔ°¡
Àû¸³±Ý : 0¿ø
Á¦Á¶»ç/¿ø»êÁö : DAIHAN/Korea
¹è¼Ûºñ : ÀϹÝ(°áÁ¦ÃѾ׿¡ µû¶ó¼­ º¯µ¿)
ÁÖ¹®¼ö·® :
°³

¡á Á¦Ç°ÄÚµå(CAT No) / °¡°ÝÇ¥(Price)
»óÇ°ÄÚµå Description ´ÜÀ§/°¹¼ö ÆǸŰ¡ VAT ÁÖ¹®Çϱâ
DH.WACS1045Autoclave, automatic 45Liter, ¥Õ300¡¿h650mm, 2kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WACS1060Autoclave, automatic 60Liter, ¥Õ350¡¿h650mm, 3kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WACS1080Autoclave, automatic 80Liter, ¥Õ400¡¿h630mm, 4kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WACS1100Autoclave, automatic 100Liter, ¥Õ450¡¿h630mm, 5kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC01047Autoclave, fuzzy control, 47Liter, ¥Õ300¡¿h670mm, 2kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC01060Autoclave, fuzzy control, 60Liter, ¥Õ350¡¿h650mm, 3kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC01080Autoclave, fuzzy control, 80Liter, ¥Õ400¡¿h630mm, 4kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC01100Autoclave, fuzzy control, 100Liter, ¥Õ450¡¿h630mm, 4kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WACS2045Autoclave, program control 45Liter, ¥Õ300¡¿h650mm, 2kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WACS2060Autoclave, program control 60Liter, ¥Õ300¡¿h650mm, 2kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WACS2080Autoclave, program control 80Liter, ¥Õ300¡¿h650mm, 2kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WACS2100Autoclave, program control 100Liter, ¥Õ300¡¿h650mm, 2kWea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC10045Autoclave Basket, wire, 45l¿ëea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC10060Autoclave Basket, wire, 60l¿ëea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC10080Autoclave Basket, wire, 80l¿ëea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC10100Autoclave Basket, wire, 100l¿ëea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC20045Autoclave Basket, perforated, 45l¿ëea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC20060Autoclave Basket, perforated, 60l¿ëea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC20080Autoclave Basket, perforated, 80l¿ëea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ
DH.WAC20100Autoclave Basket, perforated, 100l¿ëea/1°¡°Ý¹®ÀÇ°¡°Ý¹®ÀÇ


¡Ø Note! Ç¥½Ã°¡°ÝÀº ȯÀ² ¹× ¿øÀÚÀç º¯È­·Î º¯µ¿µÉ ¼ö ÀÖÀ¸¸ç ±ÇÀå ¼ÒºñÀÚ °¡°ÝÀÓ ( VAT º°µµ)¢Î 02)967-5978
¡Ø ÀÎÅÍ³Ý ÁÖ¹®ÀÌ  ºÒÆí ÇϽŠºÐÀº ÀüÈ­ ȤÀº Æѽº °ßÀû ¿äû ½Ã ´ç»ç °ßÀû ÈÄ  ÁÖ¹® °¡´ÉÇÕ´Ï´Ù.FAX:02)967-5979
¡Ø ±Ô°Ý ¿Ü ÁÖ¹®Á¦ÀÛ ¹× ºÎ´ç°¡°ÝÀ¸·Î ³»°í °¡ ÇÊ¿ä·Î ÇϽŠºÐÀº º°µµ·Î °ßÀû¿äû or ÀüÈ­¹®ÀÇ ¹Ù¶ø´Ï´Ù.

¡á ¿ëµµ(Applications)
* Top-loading Sterilizers for Easy Loading of Large Working Volume.
* Complete Safety Pressure Mechanism
* Strong and Safety Screw Handle Door
* Over Temperature, Pressure, Current protection capability, Automatic over pressure release valve ensure user safety
* Microprocessor Controlled Program Function :10 Step, 999 Cycles

¡á
Á¦Ç°Æ¯Â¡(Features)
* LCD Digital Display : ¼³Á¤¿Âµµ¿Í ÇöÀç¿Âµµ°¡ µ¿½Ã¿¡ Ç¥½ÃµÇ¸ç ¼³Á¤µÈ ¸ê±Õ¿Âµµ¿¡ µµ´ÞÇϸé Timer°¡ ÀÛµ¿µÇ¾îÀÛ¾÷¿Âµµ¿Í ¸ê±ÕÁøÇà½Ã°£ÀÌ µ¿½Ã¿¡ Ç¥½ÃµÊ.
* Safety Device : °ú¿­, °úÀü·ù ¹æÁö¿ë ¾ÈÀüÀåÄ¡±â´ÉÀÌ ÀÖÀ¸¸ç ¸ê±Õ½Ã°£ µµ´Þ ½Ã Buzzer°¡ 30ÃÊ µ¿¾È ¿ï¸®¸ç ¾Ð·ÂÀÌ ºüÁø´Ù.
* ´Ù·ç±â ½¬¿î Four Arm ±¸Á¶ÀÇ Locker
* 121¡É¿¡¼­ ¡¾0.5¡É À̳»ÀÇ ³ôÀº ¿Âµµ ¾ÈÀü¼ºÀ» Áö´Ï°í ÀÖÀ½.
* °¢ ¸ðµ¨¿¡ ¸Â´Â Perforated Basket 2°³ Æ÷ÇÔ.
* º» Á¦Ç°Àº Á¦Á¶¹° ¹è»óÃ¥ÀÓº¸Çè¿¡ ÀÇÇØ ºÒÀÇÀÇ »ç°í½Ãº¸»óÀ» ¹ÞÀ» ¼ö ÀÖ½À´Ï´Ù. (´ëÀÎ, ´ë¹° °¢°¢ 1¾ï¿ø)
* ¸¶ÀÌÅ©·ÎÇÁ·Î¼¼¼­¸¦ ÀÌ¿ëÇÑ ÇÁ·Î±×·¥½Ä ÀÛ¾÷ ¼öÇà 10 Step, 999 Cycles (Programable Controller¿¡ ÇÑÇÔ).

¡á
±Ô°Ý(Specifications)
*Incl. Wire basket 2ea ±âº»Æ÷ÇÔ
±¸ºÐ 45   60 80 100
Dimension(Inner)
(w¡¿d¡¿h) (Outer)
¥Õ300¡¿h650
680¡¿470¡¿880
¥Õ350¡¿h650
680¡¿470¡¿900
¥Õ400¡¿h630
780¡¿580¡¿900
¥Õ450¡¿h630
780¡¿580¡¿900
Heater 2 kW 3 kW 4 kW 5 kW
Capacity 45 Lit. 60 Lit. 80 Lit. 100 Lit.
Temp. Range Ambiebt 5¡É to 132¡É
Accuracy ¡¾0.5¡É at 121¡É
Display Digital LCD (PV & SV Displayed)
Controller Programmable PID Digital  Control (10-step, 999-cycle)
Time 99 hr 59 min 59 sec
Pressure 1.2 kg/§²
Gauge 0~3 kg/§²
Material Chamber
Cabinet
Stainless steel (SUS304)
Powder coated steel
Door packing One Touch Pressure Handle Type
Safety Over Temp., Over Pressure and Over Current Protector
Basket 2ea of Wire Basket included
Electric Supply 110V, 60Hz or 220V, 50/60Hz

Spare Accessories
DH.WAC10045 Wire Basket 2ea, for 45 Lit. Autoclave
DH.WAC10060 Wire Basket 2ea, for 60 Lit. Autoclave
DH.WAC10080 Wire Basket 2ea, for 80 Lit. Autoclave
DH.WAC10100 Wire Basket 2ea, for 100 Lit. Autoclave

Optional Accessories
DH.WAC20045 Perforated Basket 2ea, for 45 Lit. Autoclave
DH.WAC20060 Perforated Basket 2ea, for 60 Lit. Autoclave
DH.WAC20080 Perforated Basket 2ea, for 80 Lit. Autoclave
DH.WAC20100 Perforated Basket 2ea, for 100 Lit. Autoclave

Àü±¹ ¹è¼Û°¡´É (µµ¼­, »ê°£ ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
ÀÔ±ÝÈ®ÀÎ ÈÄ 2~4ÀÏÀ̳»(°øÈÞÀÏ Á¦¿Ü)¿¡ ¹è¼ÛµÇ¸ç µµ¼­/»ê°£Áö¿ªÀÇ °æ¿ì 1~2ÀÏ Á¤µµ Ãß°¡ ¼Ò¿äµË´Ï´Ù.
¾÷ü¹è¼ÛÀÏ °æ¿ì °³º°Åû縦 ÅëÇØ ¹è¼ÛµÇ¸ç 1~2ÀÏ Ãß°¡ µÉ ¼ö ÀÖ½À´Ï´Ù.
»óÇ°±¸¸Å¾×ÀÌ 10¸¸¿øÀÌ»óÀÎ °æ¿ì ¹è¼Û·á°¡ ¹«·áÀ̸ç 10¸¸¿ø¹Ì¸¸ÀÎ °æ¿ì¿¡´Â 5,000¿øÀÌ ºÎ°úµË´Ï´Ù(b2b°Å·¡´Â º°µµ ¹è¼Ûºñ Ã¥Á¤).
¹«·á¹è¼ÛÁ¦Ç°Àº ´ÜÇ°¿¡ ÇÑÇØ ¹«·á¹è¼ÛµÇ¸ç ±âŸ Á¦Ç°°ú µ¿½Ã ±¸¸Å½Ã ¹è¼Ûºñ Ã¥Á¤±âÁØ¿¡¼­ Á¦¿ÜµË´Ï´Ù.
´ëÇÑ°úÇÐ ¼îÇθô ¹è¼ÛÀÏ °æ¿ì02-967-5978 À» ÅëÇØ ¹è¼ÛµÇ¸ç ¹è¼ÛÇöȲÀº ÁÖ¹®/¹è¼ÛÁ¶È¸¿¡¼­ È®ÀÎÇÏ½Ç ¼ö ÀÖ½À´Ï´Ù.
±³È¯ ¹× ¹ÝÇ°ÀÌ °¡´ÉÇÑ°æ¿ì
°ø±Þ¹ÞÀ¸½Ã´Â »óÇ°ÀÇ ³»¿ëÀÌ Ç¥½Ã, ±¤°í ³»¿ë°ú ´Ù¸£°Å³ª »óÇ°ÀÌ ÆļÕ/¼Õ»óµÇ¾ú°Å³ª ºÒ·® Á¦Ç°ÀÏ °æ¿ì¿¡´Â °ø±Þ¹Þ´Â ³¯·ÎºÎÅÍ
7ÀÏ À̳»¿¡ º»»ç¿Í »ó´ãÈÄ ±³È¯ ¹× ¹ÝÇ°ÀÌ °¡´ÉÇÏ¸ç ¼ö°Å ¹× Àç¹ß¼Û ºñ¿ëÀº º»»ç°¡ ºÎ´ãÇÕ´Ï´Ù.
´Ü °í°´´ÔÀÇ ´Ü¼ø º¯½É ¶Ç´Â »ö»ó, Å©±â(ÀÇ·ù,½Å¹ß)º¯°æÀ¸·Î ÀÎÇÑ ±³È¯ ¹ÝÇ°Àº 7ÀÏ À̳»¿¡ ±³È¯/¹ÝÇ°°¡´ÉÇÏ¸ç ¼ö°Å ¹× Àç¹ß¼Û
ºñ¿ëÀ» °í°´´Ô²²¼­ ºÎ´ãÇÏ¼Å¾ß ÇÕ´Ï´Ù.

¹Ýµå½Ã 02-967-5978 À» ÅëÇØ ¹ÝÇ°ÇÏ¿©¾ß ÇÏ¸ç ±âŸ Åùè»ç¸¦ ÀÌ¿ëÇÒ °æ¿ì ¼öÃë°ÅºÎ µÉ ¼ö ÀÖ½À´Ï´Ù.


±³È¯ ¹× ¹ÝÇ°ÀÌ ºÒ°¡´ÉÇÑ°æ¿ì
°í°´´ÔÀÇ ´Ü¼ø º¯½É ¶Ç´Â »ö»ó, Å©±â µîÀÇ º¯°æÀ» À§ÇÑ ¹ÝÇ° ¹× ±³È¯½Ã¿¡´Â »óÇ°ÀÇ ÅÂ±×¿Í Æ÷Àå»óÅÂ(¹Ú½º)¸¦ º¸Á¸ÇÏ¼Å¾ß ÇÕ´Ï´Ù.
Æ÷ÀåÀ» °³ºÀÇÏ¿© »ç¿ëÇÑ ÈçÀûÀÌ Àְųª Æ÷ÀåÀÌ ÈÑ¼ÕµÇ¾î »óÇ° °¡Ä¡°¡ ÇöÀúÈ÷ »ó½ÇµÈ °æ¿ì¿¡´Â ±³È¯ ¹× ȯºÒÀÌ ºÒ°¡´ÉÇÕ´Ï´Ù. 
(¿¹: ¹ÝÇ°½Ã ¿ø¹Ú½º¿¡ ÁÖ¼Ò±âÀÔ, ¹Ú½º¿ëÅ×ÀÌÇÁ»ç¿ë, µî ¹Ýµå½Ã ´ç»ç¿¡¼­ º¸³»µå¸° 2Áß¹Ú½º·Î º¸³»ÁּžßÇÕ´Ï´Ù.)

ȯºÒ ¹× AS
ȯºÒÀº ¹Ý¼Û È®ÀÎ ÈÄ °¡´ÉÇÏ¸ç ¹Ýµå½Ã °í°´¸¸Á·¼¾ÅÍ¿Í »ó´ã ÈÄ ¹Ý¼ÛÇÏ¿©¾ß Çϸç Àû¸³±ÝÀ¸·Îµµ ȯºÒ ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù.
»óÇ° »ç¿ë¹æ¹ý ¹× »óÇ°¿¡ ´ëÇÑ ¹®ÀÇ´Â °í°´Çູ¼¾ÅÍ(02-967-5978), q&a °Ô½ÃÆÇ, 1:1¹®ÀÇ °Ô½ÃÆÇ µî¿¡ ¹®ÀÇÇϼ¼¿ä
»óÇ° »ç¿ëÁß ¹ß»ýÇÏ´Â a/s´Â ÇØ´ç ¼öÀÔ ¹× °ø±Þ¾÷ü¿Í Á÷Á¢ »ó´ãÇÏ¼Å¾ß ÇÕ´Ï´Ù.

(0) À̸§ Á¶È¸ µî·ÏÀÏ ´äº¯
 »óÇ°¿¡ ´ëÇÑ ¹®ÀDZÛÀÌ ¾ø½À´Ï´Ù

(0) À̸§ Á¶È¸ µî·ÏÀÏ
 »óÇ°¿¡ ´ëÇÑ Æò°¡±ÛÀÌ ¾ø½À´Ï´Ù



»ç¾÷ÀÚ µî·ÏÁõ &..
ȨÆäÀÌÁö ¾÷±×·¹..
¿Â¶óÀÎ °ßÀû¹× ..
Á¾ÇÕ Ä«´Þ·Î±× ..
A/S Á¢¼ö¾È³»
°ßÀû ¿äû
°ßÀû¿äûÇÕ´Ï´Ù.
°ßÀû ºÎŹµå¸³´Ï´Ù.
°ßÀûºÎŹµå¸³´Ï´Ù. ^^
°ßÀû ºÎŹ µå¸³´Ï´Ù.
UP351 Program Controller ..
Yokogawa CW-240 Çѱ۸޴º..
¿Âµµ & ½Àµµ ´ÜÀ§ °ü·ÃÀÚ·á
°¡½º³óµµ ¿ë¾îÇؼ³
RE:°¡½º³óµµ ¿ë¾îÇؼ³
±â±â A/S ¼ö¸® ¹®ÀÇ
°Ô½ÃÆÇÀÇ ¼º°Ý°ú ¸ÂÁö ¾Ê´õ..
°è´Ü ¿î¹ÝÂ÷ -600kg
ÇÇÆ꺸ÀÌ ¹®ÀÇÇÕ´Ï´Ù.
¸¶Á¶´Ï¾Æ°ü ¹®ÀÇ
ȸ»ç¼Ò°³ ¤Ó °³ÀÎÁ¤º¸º¸È£Á¤Ã¥ ¤Ó ÀÌ¿ë¾à°ü ¤Ó °í°´¼¾ÅÍ
¼­¿ï : ¼­¿ï Á¾·Î±¸ Àͼ±µ¿ 55¹øÁö Çö´ë¶ß·¹ºñ¾Ó 422È£ (Hyundai Tres Bien@422 Iksun-dong 55 Jongno-Gu Seoul, Korea) (110-340)
Tel : 02-967-5978 (010-3768-8228)   Fax : 02-967-5979   E-mail : dhslkorea@naver.com
»ç¾÷ÀÚµî·Ï¹øÈ£ : 209-04-47629 ´ëÇ¥ : ±è¹Î¿Á   ½Ã°èÅë½ÅÆǸž÷½Å°í¹øÈ£ : Á¾·Î 01-3204
Copyrights ¨Ï ´ëÇÑ°úÇÐ All replica reserved.
Table 'dhslkorea2.kimson_referer' doesn't exist